3.14

Connection Health and Building Info

Four tabs

The panel opens on Dashboard, with Connection Health, Building Info and Settings beside it. The tab you choose is kept in the page address, so reloading the page, the back button, or a bookmark brings you back to it. On a phone the four tabs share the width of the screen.

Connection Health

Connection Health replaces the Diagnostics section. It lists every machine you added, one row each, with a badge that reads OK, Needs attention or Nothing to check:

  • Readings. Whether the machine’s readings arrive and change. Readings are taken about every 5 minutes and uploaded about once an hour, so a machine is flagged when its newest reading is more than 90 minutes old, or when its values have not changed for 6 hours.
  • Command. For heating and cooling, how often the thermostat was in the mode it was sent and held the setpoint it was sent, the average and largest setpoint gap, and fan speed where the thermostat reports it. Only the comparisons a unit has data for are shown. A thermostat in heat or cool mode that sits idle between cycles counts as matching the mode it was sent. EV chargers, home batteries, pool pumps, and water heaters run through a switch are compared with their plan: how often each reading was on or off when the plan said so, and how many readings came back unavailable.
  • Sensors. How often each extra sensor you mapped carried a value over the last 6 hours.
  • Power. For a machine with its own power sensor, how many readings carried power and how often its draw matched the commands. Power readings inform the check and never raise an alert on their own.

Machine types you have not added appear below, greyed out. About these checks, at the bottom, explains what each check compares, when it flags a machine, and what to do. The version numbers at the foot of the old Diagnostics section are gone.

Alerts on the Dashboard only for clear failures

The Dashboard shows a strip above your cards only when a machine has clearly stopped working: its readings stopped or froze, a thermostat did not hold the setpoints it was sent, or a sensor you mapped almost never reports. The strip names each machine and links to Connection Health. A sensor that reports some of the time, a thermostat set to a different mode that still holds the temperature, advice about your comfort range, and solar that reads zero at night do not raise it.

Building Info

  • Your metrics for the last 30 days: modeled and measured savings, the machine types you have connected, hours your machines sat idle at the priciest times, the share of your energy used in the cheapest hours, and the comfort range you gave the optimizer. A chart shows savings per day, and another shows the hours of the day when you adjust the plan.
  • How you compare, ranked against similar Hungry Machines homes, without showing anything about them.
  • Badges and streaks: your savings streak, and the Peak Dodger, Full House and Room to Move badges.
  • Your home: plain facts learned from your readings, such as how fast each room drifts with the system off, how much the midday sun adds, how fast a unit heats or cools at full output, how far a unit’s own sensor reads from your room sensor, how much heat a water heater’s tank loses when idle, and how much of its rating a solar array produces in full sun. A unit without enough readings says it is still learning. The facts are approximate and change with the seasons.

Temperatures on every tab follow your chosen unit, °F or °C.

A power sensor for every machine

The form for an EV charger, home battery, water heater, home robot, pool pump or hot tub has an optional Power sensor: a sensor.* that measures that machine alone, in W or kW. When the form recognizes your device it can fill this in for you. The integration then uploads the machine’s power draw and its device state with every reading, so Connection Health can tell an unavailable device from one that is off.

Also in this release

  • The panel and cards keep you signed in between visits, and through a short outage of the service or your internet.
  • The integration waits out a short outage instead of asking for your password again.
3.13

Setpoints that follow your room sensor, a quick comfort preset, and rebuilt cards

Units that read the room differently from your sensor

A window unit or mini-split reads the room from its own built-in sensor, which can sit a degree or more from the room sensor you mapped to it. Set to 69 °F, such a unit stops at 69 °F on its own sensor while your room sensor still reads 71 °F. Your comfort range is about the room, so Hungry Machines now moves the unit’s setpoint until your room sensor reads the planned temperature, in heating and cooling.

  • The setpoint can sit up to 3 °F outside your comfort range. It leaves the range only while the unit’s own behaviour shows the disagreement: idle while the room is short of its target, or still running while the room is past it.
  • A unit that reaches that limit is flagged in its comfort settings. Wider setpoint offset raises the limit to 6 °F for that unit. You can also map a different temperature sensor, or widen the range.
  • The comfort table marks any hours too narrow for a unit to hold and says how wide they need to be. It is advice and does not block saving.

Quick preset

The HVAC editor fills the hourly comfort table in one step. Set a base temperature, the times you leave and return, and a Tight (±2 °F), Default (±5 °F) or Wide (±10 °F) range for the hours you are away. Every hour stays editable.

Rebuilt dashboard cards

  • Thermostat card. Shows the room temperature and what the thermostat is set to with no setup, draws today’s comfort range, and says when a unit is paused, on an idle day or on a warm-up test.
  • Savings card. Lists each appliance with its own estimate and its next scheduled run, and shows a sensor problem on the unit’s row.
  • Both reload the plan about every five minutes and link to the panel.

Also in this release

  • Pausing from the panel takes effect within seconds.
  • The freeze floor is designed to return the thermostat to its earlier setpoint as well as its mode, including after a Home Assistant restart.
  • Diagnostics names any unit whose readings have stopped or are not changing, and lists the sensor differences measured for each unit.
3.12

Pools, hot tubs, and a form that finds your devices

Pool pump

Add a pool pump as its own appliance. Tell it how many hours to run each day and the window you allow, and the plan places those hours in the cheapest half-hours of the window.

Hot tub

Add a hot tub with a ready temperature, an eco temperature, and up to four soak times, each on the days of the week you choose. The tub drifts toward eco between soaks, and the plan is designed to have it back at ready before the next one. Its card plots the water temperature against both limits.

Water heater: lowest temperature and sanitize cycle

  • Lowest temperature. A temperature that plans are designed to keep the tank above, 120 °F by default.
  • Sanitize cycle. Schedules heating the tank to a temperature you choose (140 °F by default) and holding it for an hour every two days, in the cheapest half-hours that fit. On by default, and it needs the tank’s own thermostat set at least that high.
  • The water heater card shows when the next cycle runs and whether the last one reached its temperature.

Add appliances faster

  • The entity picker groups likely matches under Suggested. Every other entity is still listed below.
  • Pick a device and its temperature or battery sensor is filled in for you.
  • The first step offers devices it recognized in your home, so a tub, pump or robot vacuum takes one tap to add.

Also in this release

  • Run warm-up button on each HVAC card schedules the one-time warm-up for the next suitable day.
  • On heating days, an idle thermostat now stays in heat at the bottom of your comfort range instead of switching off, so the thermostat holds that temperature on its own if Home Assistant stops.
  • Smoother comfort protection in narrow comfort ranges and in Auto mode.
3.11

A comfort range for each day, and timed pauses

A comfort range for each day of the week

The HVAC editor has a new Days choice: one range for every day, one for weekdays and one for weekends, or one for each day. Each night’s plan uses that date’s range, and the dashboard chart and thermostat card follow today’s.

Pause a unit for 2, 4 or 6 hours

  • Each HVAC card and the thermostat card have Pause 2 h, Pause 4 h and Pause 6 h buttons.
  • A paused unit is yours. The card shows when the plan resumes, and Resume now ends the pause early.
  • New hungry_machines.pause and hungry_machines.resume services do the same from an automation.
  • The freeze floor still acts during a pause.

Chart scales

A new Chart scale setting. Standard keeps each appliance’s fixed range. Dynamic fits the chart to your comfort range and setpoints. Solar charts choose between your system size and the day’s peak.

Measured solar on the solar card

With a production sensor, the card plots today’s measured output over the forecast, refreshed every 5 minutes, and shows the kWh you made so far against the forecast.

3.11.1

  • The solar card shows whether your production sensor is connected: reporting, unavailable, missing, or not chosen.
  • An evening change to your comfort settings now takes effect that night.
3.10

Celsius, Auto mode, and idle days

Choose °F or °C

Settings has a Temperature units selector: °F, °C, or Home Assistant’s own setting. The panel, cards, charts and editors all show and accept the unit you choose. Metric Home Assistant installs are now supported.

Auto mode chooses heating or cooling for you

With a device on Auto, Hungry Machines switches your thermostat to heating or cooling for each day’s plan, based on how your own home responds to the weather. If the room leaves your comfort range the other way, it switches to bring the room back. Prefer to choose yourself? On Heating only or Cooling only, your thermostat’s mode wins, and a thermostat you turn off is left off.

Idle days

On a mild day, when your home should stay inside your comfort range with nothing running, no heating or cooling is planned. Comfort protection still steps in if the forecast turns out wrong.

Freeze floor

If a room falls below 50 °F, Hungry Machines is designed to heat it to 52 °F and then return the thermostat to the mode it was in, even when optimization is paused. It is a backstop that works while Home Assistant is running, not a replacement for your thermostat’s own freeze protection.

Simpler export rates

Pick how your utility credits the solar power you send back: market price, your regular rates, your own 24 hourly rates, or no credit. ComEd and Ameren Illinois customers choose by when net metering started. The solar card now plots the export price.

Also in this release

  • Time zone in Settings keeps your plans and prices lined up with your local day.
  • Home Assistant’s log now says when uploads, your solar sensor, today’s plan and each thermostat start working, fail or recover.
  • Uploads recover on their own after a long outage.
3.9

Home power limits and a simpler comfort table

Home power limits

A new Settings section: how many appliances may run at once, a whole-home power cap, an always-on reserve, and a demand charge with an optional on-peak window. Leave any field blank for no limit. HVAC is planned first, and your other appliances are planned around it.

The hourly comfort table is now the main control

Settings shows one low and high limit for each of the 24 hours. Reset to defaults refills the table with a pre-cooling shape: a tight range overnight and a wider one through the day. Your saved limits load as before.

Plug-in and balcony solar

Smart plugs on plug-in inverters are now read correctly, and the solar picker names plug-in and balcony arrays.

3.9.1 and 3.9.2

  • The integration carries its own icon on Home Assistant 2026.3 and later.
  • The command check moved beside Sensor health in Diagnostics, and a paused unit no longer triggers a warning.
  • New accounts start in your Home Assistant time zone.
3.8

Steadier room temperatures

  • Hungry Machines now adjusts the setpoint in small steps through the day to keep the room on its planned temperature.
  • Comfort protection steps gently toward your range instead of jumping across it.
  • Readings keep flowing on a slow connection.
3.7

Your room sensor leads

  • If you chose a room sensor, it is now the temperature Hungry Machines plans around and checks against, ahead of the thermostat’s own reading.
  • Savings read as “est. N% savings today”, with the basis on hover.
  • Diagnostics shows the integration version.
3.6

Price spike guard

On a real-time rate such as ComEd Hourly Pricing, prices sometimes run far above the day-ahead forecast. When a spike develops, Hungry Machines re-plans the rest of your day and your home picks up the new plan within minutes. Turn it off any time in Settings → Price spike guard. Plans work within your comfort range either way.

3.5

Solar that learns your array

  • Production sensor. Point your solar appliance at a sensor reporting the array’s output and Hungry Machines learns your real yield and shading.
  • Solar card. Plots the day’s generation over the price bars with expected kWh, and names the forecast it used.
  • Export rates. Tell Hungry Machines what your utility pays for power you send back, and plans value your daytime surplus at that price.
  • ComEd Delivery Time-of-Day. Pick your delivery plan under Dynamic pricing and edit its period prices.
3.4

Comfort protection, all day

Every 5 minutes, Hungry Machines checks each room against the low and high limits you set. If the room crosses one, it steps in to bring the room back, spacing its commands to avoid short-cycling your compressor. It works for every home with nothing to turn on, and uses your room sensor when the thermostat reports no temperature.

3.3

Home robots

Add a robot vacuum or mower, set a daily Tasks window and a target charge, and the plan schedules dock charging in the cheapest half-hours before the window. Hungry Machines only sends the robot to its dock. It does not start tasks.

3.2

Per-device control

  • An optimization toggle on every controllable card, so you can pause one device and leave the rest running.
  • A clear choice between Simple and Custom comfort schedules.
  • Each HVAC’s own comfort range on the dashboard charts.
3.1

Dehumidifiers

Add a dehumidifier as an appliance. This first release records its use; planning comes later.

3.0

More than one HVAC, and live prices

  • Multiple HVAC units. Register each unit with its own thermostat and sensors. Each gets its own plan, comfort editor and pause toggle, and both cards can show one unit or the whole home.
  • Dynamic pricing. Follow live wholesale prices for your grid region, starting with ComEd and Ameren Illinois, plus an estimate of your delivery charge.
  • Send feedback from Settings.
  • All pricing controls in one Pricing source section.

Earlier releases

Versions 0.1 through 2.9 built the foundation: the sidebar panel, the thermostat and savings cards, nightly plans for HVAC, EV chargers, batteries and water heaters, time-of-use pricing zones, sensor health, and the one-time warm-up.

Join Our Newsletter